We coordinate China supplier matching for prefabricated homes, normalize quotations and arrange sample and inspection requests. A common revision connects the supplier’s offer to the buyer’s brief. Consolidation and export coordination use a separate packing and shipment record.

Engineer comparing a portal sketch with a load table
Design loads
Wind speed, ground snow and seismic basis are columns, not adjectives.
Steel grade
Heat or coil identity stays with the member mark on the drawing.
Fire strategy
Core, joints, doors and penetrations are separate lines in the matrix.

Design basis, two columns that must not be mixed

Treat the catalog screen as an input for shortlisting. Ask each candidate to identify which values it has assumed, and have the destination project team confirm which design criteria apply. The numbers shown below illustrate different fields in a comparison and are not product performance claims.

Item Screened model Project calculation
Wind 0.50 kPa service pressure used to check a 50 mm wall family Design wind speed from the local code, example band 45 m/s when the brief says so
Snow Not included in the 0.50 kPa wall screen Ground snow load, example 1.5 kN/m2, with drift rules if the roof steps
Seismic Not stated Seismic design basis such as 0.30 g, when the geotechnical note supplies it
Envelope 50 mm panel, core unnamed 50-100 mm wall, U-value target 0.25-0.60 W/m2K, thermal bridge at the rim called out
Code path None Relocatable building or permanent modular construction, chosen with the authority having jurisdiction

Volumetric modules can arrive with more interior work complete. Folding or panelized units can fit a denser load, but leave more joints for the site crew. Before pricing either route, ask for the measured shipping envelope, actual gross weight, container loading plan and foundation interface.

Material and weld sequence

These checkpoints describe what to capture from the shortlisted supplier before production release. The buyer agrees the inspection scope and acceptance criteria with the supplier and inspection provider.

  1. 01

    Traceability rule written

    For CFS studs and heavier steel members, request the grade, mill certificate, and a link from heat or coil number to part identification. Record which components fall outside the traceability request.

  2. 02

    Coating repair at welds

    Compare galvanizing and paint by exposure class, coating mass or film thickness, and weld repair instructions. Where Z275 is specified, ask for the supplier record and verify which pieces it covers.

  3. 03

    Welded frame versus bolted knock-down

    A welded frame retains more shop assembly but occupies more shipping space. A bolted knock-down frame may pack more tightly and requires field fit and torque checks. Ask who records inspection of the connection after assembly.

  4. 04

    Opening-unit dimensional review

    Request a first-unit review before a batch is released. Compare lifting-point coordinates, hole patterns and panel thickness against the drawing revision. Record and resolve discrepancies with the supplier before the buyer accepts the next stage.

Documents to request from suppliers

Ask for a document list with an issuer, revision and intended use for each item. Supplier capabilities, certificates and technical approvals must be checked for the specific sourcing request.

Ask for the revision that matches the country

Share the destination, quantity and release milestones. We can prepare a common request for quotation and an evidence checklist for shortlisted suppliers.